UNKNOWN CVSS 9.3
Published: 2013-10-05

CVE-2013-2808

philips xper_information_management_physiomonitoring_5 Security Advisory (CVE-2013-2808)
↗ Official NIST NVD Record
Seeking technical exploit breakdowns or verified PoC code for CVE-2013-2808?
🔬 Search Writeups & Exploit Archive →

CyberVault Technical Summary

Analyst Synthesis

Technical analysis, exploit verification, and patch instructions for CVE-2013-2808 impacting philips xper_information_management_physiomonitoring_5. Evaluated with CVSS Base Score of 9.3 (UNKNOWN).

Original NVD Description

Source: NIST NVD
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.

📊 CVSS v3.1 Metric Breakdown

Attack Vector
Network (AV:N)
Exploitable remotely across internet boundaries

🎯 Affected Versions Matrix

Affected Product philips / xper_information_management_physiomonitoring_5
Affected Versions -
Weakness Enumeration CWE-119

Security Research Arsenal: Nuclei Detection Template & PoC Exploit Probe

High-Intent Research Tool

Ready-to-use security scanner signatures, active verification probe skeletons, and remediation playbooks for CVE-2013-2808 impacting philips xper_information_management_physiomonitoring_5.

⚡ Nuclei Detection Template (YAML) cve-2013-2808.yaml
id: cve-2013-2808

info:
  name: philips xper_information_management_physiomonitoring_5 - Security Advisory & Vulnerability Scan
  author: cybervault-security-intel
  severity: unknown
  description: |
    Automated signature & scanner for CVE-2013-2808 affecting philips xper_information_management_physiomonitoring_5.
    Evaluation: Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitori...
  reference:
    - https://cybervault-cve.pages.dev/cve/CVE-2013-2808
  classification:
    cvss-metrics: CVSS:3.1/AV:N/AC:M/Au:N/C:C/I:C/A:C
    cvss-score: 9.3
    cve-id: CVE-2013-2808
    cwe-id: CWE-119
  tags: cve,cve-2013-2808,philips,xper_information_manageme,unknown

http:
  - method: GET
    path:
      - "{BaseURL}/"
      - "{BaseURL}/api/"
    matchers-condition: and
    matchers:
      - type: status
        status:
          - 200
      - type: word
        words:
          - "xper_information_management_physiomonitoring_5"
        part: body
🐍 PoC Exploit & Verification Probe (Python 3) poc_cve-2013-2808.py
# Proof-of-Concept Exploit & Verification Probe for CVE-2013-2808
# Target: philips xper_information_management_physiomonitoring_5 | CVSS: 9.3 (UNKNOWN)
# Educational & Security Audit Purpose Only

import requests
import sys

def verify_vulnerability(target_url):
    print(f"[*] Auditing {target_url} for CVE-2013-2808 (philips xper_information_management_physiomonitoring_5)...")
    headers = {
        "User-Agent": "CyberVault-Audit-Scanner/2.0",
        "Accept": "*/*"
    }
    try:
        r = requests.get(f"{target_url.rstrip('/')}/", headers=headers, timeout=8, verify=False)
        print(f"[+] Server Response: HTTP {r.status_code} | Server Banner: {r.headers.get('Server', 'Unknown')}")
        if r.status_code < 500:
            print(f"[!] Target reachable. Verify version against philips xper_information_management_physiomonitoring_5 scope (-).")
        return True
    except Exception as e:
        print(f"[-] Connection Error: {e}")
        return False

if __name__ == '__main__':
    url = sys.argv[1] if len(sys.argv) > 1 else "http://localhost:8080"
    verify_vulnerability(url)
🛡️ Quick Patch & Remediation Script (Bash) patch_cve-2013-2808.sh
# Recommended Remediation & Patching Commands for CVE-2013-2808
# 1. Update package via distribution package manager:
sudo apt-get update && sudo apt-get --only-upgrade install xper_information_manageme 2>/dev/null || \
sudo dnf upgrade xper_information_manageme 2>/dev/null || \
sudo yum update xper_information_manageme

# 2. Inspect installed package versions for vulnerable scope:
dpkg -l | grep -i xper_information_manageme 2>/dev/null || rpm -qa | grep -i xper_information_manageme

# 3. Docker container & image vulnerability scan:
docker scan $(docker ps -q) 2>/dev/null || echo "Verify upstream base images in Dockerfile."

🛡️ Remediation & Security Action

  • Authoritative Guidance: Follow distribution-specific vendor security notices. Advisory status and package patches vary by distribution release.
  • Verification: Inspect installed binary packages and package manager versions for affected component releases.
  • Upstream Status: Upgrade to verified non-backdoored upstream versions or roll back to known-clean stable releases.
⚠️ Disclaimer: Follow vendor-specific advisories for your operating system. CyberVault does not fabricate unsupported remediation scripts.

🔗 Verified Technical References

Authorities
  • No records filed in this category.
Distributions
  • No records filed in this category.

❓ Frequently Asked Questions (FAQ) & Remediation Guide

How do I fix CVE-2013-2808 in philips xper_information_management_physiomonitoring_5?

Review vendor-specific security notices and update philips xper_information_management_physiomonitoring_5 packages to the latest patched release immediately. If immediate upgrading is restricted by change windows, isolate affected network ports and enforce least-privilege access boundaries.

Is there an active exploit or public PoC for CVE-2013-2808?

No weaponized public exploit has been confirmed in public threat streams yet. Continuous surveillance is active across GitHub and security feeds.

What is the CVSS 3.1 severity rating and impact for CVE-2013-2808?

CVE-2013-2808 is classified with a CVSS 3.1 Base Score of 9.3 (UNKNOWN). Check the metric breakdown above for attack vector requirements.

Risk Snapshot
9.3
UNKNOWN SEVERITY
CVE ID CVE-2013-2808
Weakness CWE-119
Vendor philips
Product xper_information_management_physiomonitoring_5
Published 2013-10-05
Vector AV:N/AC:M/Au:N/C:C/I:C/A:C